The Warren-Knight Telemetric Alignment System (WK-34-7000) is designed to facilitate combat system leveling and other alignment applications by providing a quick and simple method to measure differential angles between two or more planes.
The Warren-Knight system shown features sensors—accurate to within ± 10 arc seconds. The sensors are encased in a sturdy aluminum housing each with a precision machined base. The sensor heads have a sturdy precision-machined housing with flat base . The collection device features two ports for connecting sensor heads and additional port for connecting an external power supply or connecting directly to a personal computer for data storage.
Features:
- Basic system: (2) ± 10-degree sensors capable of being mounted up to 1,000 meters from the central data collection device that are mounted to right-angle plates, and a hand-held collection device.
- Sensor Range: ± 10 Degrees
- Limits Error: ± 10 Seconds of Arc
- Dimensions: 6” x 4” x 4”
- Connection Cable: 15 meter standard length – longer lengths available.
- Ext. Power Supply: +12… +48 V DC
- Batteries: 250 mW
- Output Data: RS 485
- Weight: 15 lbs total system.